Groupe Alphard / Geosynthetics
Geomembrane leak detection
Water puddle method.
Locate punctures caused during installation of an exposed geomembrane using an electrical leak location method.
Check integrity.
Locate defects.
Water puddle method
The water puddle method allows technicians to identify and locate potential leaks, faults or tears in a geomembrane occurring during installation

How it works
How does the inspection work?
It applies a geoelectrical technique that harnesses the electrical insulation properties of geomembrane materials. (see figure below). A DC voltage is applied to metal roller that sprays water across the geomembrane service and a grounding electrode is placed in the earth outside of the test site, creating a difference in electrical potential between the roller and the underside of the membrane.
If the roller passes over any faults sufficiently large for the water to leak through the circuit between the roller and the grounding electrode is completed, and a technician is notified by their detection equipment. As it only requires a thin layer of water to be applied gradually to the geomembrane, the water puddle method allows for technicians to perform tests with 100% coverage even on extreme slopes and uneven surfaces, with a resolution capable of identifying leaks and faults smaller than 1mm2. Groupe Alphard applies the method as standardised by ASTM standard D7002.
The principle illustrated
Understanding the path of the current.
An Alphard project
Tundra Mine: bituminous geomembrane quality control
Northwest Territories, Canada · 2012–2014
As part of the Tundra Mine remediation project, Groupe Alphard implemented the lining system quality control program. The mandate included water puddle and dipole leak location surveys on the bituminous geomembrane, installation monitoring and preparation of a final report.
Explore this projectYour next project
Need to inspect a containment structure?
Let’s discuss your geomembrane and the conditions for carrying out an inspection at your site.